Optical Swing Turnstile
Safety
Design
Cost
Easy installing, NO need any professional electrician skills
Just fix the screws on the ground and connect to power supply
Model No | DS2000 | DS212P | DS210Z | DS212Z | DS213Z | DS8000 | DS205 |
Framework Material | 304 Full Stainless Steel | 304 Full Stainless Steel | 304 Full Stainless Steel | 304 Full Stainless Steel | 304 Full Stainless Steel | 304 Full Stainless Steel | 304 Full Stainless Steel |
Arm Material | Plexiglas – transparency | Plexiglas – transparency | Plexiglas – transparency | Plexiglas – transparency | Plexiglas – transparency | Plexiglass / Stainless Steel | Plexiglass / Stainless Steel |
Dimension | 1400 * 280 * 1000mm | 1600 * 210 * 1000mm | 1200 * 185 * 1020mm | 1400 *185 * 1020mm | 1540 *185 * 1020mm | 168 * 1050mm | 168 * 1050mm |
Net Weight | 70kg/pcs | 70kg/pcs | 60kg/pcs,80kg/pcs | 75kg/pcs,95kg/pcs | 80kg/pc,100kg/pcs | 60kg/pcs | 25kg/pcs |
Passage Width | 600-900mm (One passage) | 600-1200mm (One passage) | 600-1200mm (One passage) | 600-900mm (One passage) | 600-1200mm (One passage) | 600-900mm (One passage) | 600-1200mm (One passage) |
Passing Direction | Single / Bi-directional | Single / Bi-directional | Single / Bi-directional | Single directional / Bi-directional | Single directional / Bi-directional | Single directional / Bi-directional | Single directional / Bi-directional |
Power Supply | AC220V/110V, 50/60Hz | AC220V/110V, 50/60Hz | AC220V/110V, 50/60Hz | AC220V/110V, 50/60Hz | AC220V/110V, 50/60Hz | AC220V/110V, 50/60Hz | AC220V/110V, 50/60Hz |
Operation Voltage | 24V DC | 24V DC | 24V DC | 24V DC | 24V DC | 24V DC | 24V DC |
Power Consumption | 40W | 40W | 40W | 40W | 40W | 40W | 40W |
Operation Temperature | -15 °C – 60 °C | -15 °C – 60 °C | -15 °C – 60 °C | -15 °C – 60 °C | -15 °C – 60 °C | -15 °C – 60 °C | -15 °C – 60 °C |
Operation Humidity | 0 ~ 95% (No freeze) | 0 ~ 95% (No freeze) | 0 ~ 95% (No freeze) | 0 ~ 95% (No freeze) | 0 ~ 95% (No freeze) | 0 ~ 95% (No freeze) | 0 ~ 95% (No freeze) |
Working Environment | Indoor / Outdoor | Indoor / Outdoor | Indoor / Outdoor | Indoor / Outdoor | Indoor / Outdoor | Indoor / Outdoor | Indoor / Outdoor |
Flow Rate | 35-40 people per minute | 35-40 people per minute | 35-40 people per minute | 35-40 people per minute | 35-40 people per minute | 30 people per minute | 30 people per minute |
LED Indicator | Yes | Yes | Yes | Yes | Yes | Yes | No |
Emergency | Automatic arm drop when power off | Automatic arm drop when power off | Automatic arm drop when power off | Automatic arm open when power off | Automatic arm open when power off | Automatic arm open when power off | Automatic arm open when power off |
Infrared Sensor | 5 pairs(standard) | 5 pairs(standard) | 4 pairs(standard) | 6 pairs (standard) | 6 pairs (standard) | Optional | Optional |
Communication | Dry contact, Relay signal, RS485 | Dry contact, Relay signal, RS485 | RS485, TCP/IP (need access controller) | Dry contact, Relay signal, RS485 | Dry contact, Relay signal, RS485 | Dry contact, Relay signal, RS485 | Dry contact, Relay signal, RS485 |